Repository logo
Communities & CollectionsBrowse
A A A
ENPL
  • Log In
Repository logo
  1. Home
  2. Knowledge
  3. Research Data
  4. Comparison of the response to local fire of beams made of wood-CFRP composite (BSH-CFRP) and glue laminated timber (BSH)

Publication details

Alternative title
Porównanie odpowiedzi na miejscowe działanie ognia belek wykonanych z kompozytu drewno-CFRP (BSH-CFRP) i drewna klejonego (BSH)
Type
Description research data
Authors / Creators
Kawecki, Bartosz  

Pieńko, Michał  

Lipecki, Tomasz  

Stachowicz, Andrzej  
Date
2022-07-20
Deposit location
RepOD
Deposit location URL
https://repod.icm.edu.pl/dataset.xhtml?persistentId=doi:10.18150/KMOJZL
DOI
10.18150/KMOJZL

Abstracts and keywords

Abstract (PL)

W ramach projektu przeprowadzono miejscowe spalanie 24 belek o wymiarach konstrukcyjnych, wykonanych z kompozytu drewno-CFRP (BSH-CFRP) oraz drewna klejonego (BSH) pod stałym obciążeniem, w schemacie trójpunktowego zginania, w najbardziej obciążonym przekroju – na środku belki. Wytężenie każdej z próbek wynosiło 90% wytrzymałości drewna GL24h na zginanie. Zgodnie z obliczeniami, belki wzmocnione (BSH-CFRP) wymagały przyłożenia znacznie większej siły niż belki bez wzmocnienia (BSH). Wymiary przekrojów określono na podstawie dostępnych taśm CFRP (szerokości 100 mm, 120 mm, 150 mm), obliczeń Metodą Elementów Skończonych, maksymalnej siły, którą można było uzyskać na samodzielnie zaprojektowanym i wykonanym pilotażowym stanowisku badawczym oraz czasu spalania, w którym możliwe było utrzymanie odpowiedniego płomienia. W celu uzyskania wyników ważnych statystycznie przebadano po 4 próbki dla każdego przekroju. Mierzone były następujące parametry: czas spalania do momentu zniszczenia belki oraz przyrost ugięcia i temperatura elementu podczas działania ognia. Podsumowując otrzymane wyniki, wyraźnie zauważalny jest pewien trend pozwalający stwierdzić, że taśmy CFRP stosowane wewnątrz przekroju mogą zwiększać odporność ogniową dźwigarów drewnianych. Taśmy muszą być jednak umiejscowione tak, żeby były chronione przez drewno w czasie oddziaływania ognia. W niniejszych badaniach zostało to zapewnione odpowiednią szerokością przekroju. W przypadku niewielkich szerokości lub zbyt małych odległości taśm CFRP od krawędzi przekroju może dochodzić do zmniejszenia odporności ogniowej względem elementów niezbrojonych. Warto zauważyć, że przebieg zniszczenia belek bez taśmy i z taśmą CFRP był odmienny. Pierwsze ulegały gwałtownemu pękaniu, natomiast drugie charakteryzowały się pewną ciągliwością.

Zamieszczone datasety zawierają łącznie wyniki badań 24 belek (.ZIP), w skład których wchodzą pomiary ugięcia, temperatury i czasu. Dodatkowo zamieszczono plik zawierający tabele ze wstępną analizą danych (.ZIP).

Abstract (EN)

The project included local combustion of 24 beams with structural dimensions made of wood-CFRP composite (BSH-CFRP) and glue laminated timber (BSH) under a constant load, in a three-point bending, in the most loaded cross-section – in the middle of the beam. The effort of each sample was 90% of the GL24h wood bending strength. According to the calculations, the reinforced beams (BSH-CFRP) required applying a much higher force than the beams without reinforcement (BSH). The dimensions of the cross-sections were determined based on the available CFRP tapes (widths 100 mm, 120 mm, 150 mm), FEM calculations, the maximal force that could be provided on a self-designed and self-constructed pilot test stand and the burning time, during which it was possible to keep a proper flame. In order to get statistically valid results, 4 specimens were tested for each cross-section. The following parameters were measured - combustion time up to the beam destruction, the deflection increment and the temperature of the sample during fire. Summarising the got results, a certain trend is clearly noticeable, which shows that CFRP tapes used inside the cross-section can increase the fire resistance of wooden girders. However, the tapes must be positioned in the way that they are protected by the wood during the fire exposure. In this study, it was provided by the appropriate cross-section width. With small widths or too small distances of CFRP tapes from the cross-section edge, the fire resistance may be reduced comparing to non-reinforced elements. It is worth noting that the failure behaviour of the beams without and with the CFRP tape was different. The former cracked rapidly, while the latter showed some ductility.

Provided datasets include results for 24 beams (.ZIP), which contain measurements of deflection, temperature, and time. The additional file presents tables with initial analysis of the data (.ZIP).

Keywords PL
kompozyt drewno-CFRP
belki BSH-CFRP
drewno klejone
belki BSH
miejscowe działanie ognia
trójpunktowe zginanie
spalanie pod stałym obciążeniem
Keywords EN
wood-CFRP composite
BSH-CFRP beams
glue laminated timber
BSH beams
local fire
three-point bending
combustion under constant load

Additional information

Related publications
https://doi.org/10.5281/zenodo.6855058
Additional information
Powiązana publikacja stanowi dokumentację zdeponowanego zbioru danych.

Project information

Project description
MINIATURA
Project identifier
2021/05/X/ST5/00519
Funding Institution
Narodowe Centrum Nauki (NCN)
Kawecki, B., Pieńko, M., Lipecki, T., & Stachowicz, A. (2022). Comparison of the response to local fire of beams made of wood-CFRP composite (BSH-CFRP) and glue laminated timber (BSH) (, Ed.) [Data set]. https://doi.org/10.18150/KMOJZL
Loading...
Thumbnail Image
License
CC-BY - Attribution
CC-BY - Attribution
Accessibility issue?Request a WCAG-compliant file
Publication available in collections
Research Data
Scientific and Technical Information Centre of Lublin University of Technology
  • ul. Nadbystrzycka 36 C20-618 Lublin
  • Phone Icon+48 81 538 46 86
  • Emailoab@pollub.pl
Repository of Open Collections and Knowledge
About repository
Instructions for depositing
Regulations
Privacy policy
Accessibility statement
DSpace Software
Human Resources Strategy for Researchers (HRS4R) at Lublin University of Technology
Powered by Dspace 10
Copyright Politechnika Lubelska © 2026