Abstract (PL)

Niniejsza praca doktorska pt. "Zapewnienie ciągłości zasilania sieci średniego napięcia podczas awarii, prac eksploatacyjnych oraz diagnostyki kablowej" skupia się na opracowaniu i wdrożeniu nowoczesnych metod mających na celu zwiększenie niezawodności sieci elektroenergetycznych średniego napięcia. Wyładowania niezupełne, są lokalnymi wyładowaniami częściowo przebijającymi izolację kabli, stanowią jedno z głównych zagrożeń dla ich długotrwałej niezawodności. Wczesne wykrywanie i analiza wyładowań niezupełnych są niezbędne w celu zapobiegania poważnym awariom oraz zmniejszenie kosztów utrzymania sieci. W pracy szczegółowo omówiono różne typy kabli średniego napięcia, w tym kable o izolacji papierowo-olejowej oraz polietylenowej, wraz z ich charakterystycznymi defektami. Przedstawiono również metody diagnostyczne, zarówno konwencjonalne, jak i niekonwencjonalne, takie jak próby napięciem przemiennym, bardzo niskiej częstotliwości, tłumionym napięciem przemiennym oraz detekcja elektromagnetyczna, elektryczna, akustyczna i optyczna. Centralnym elementem rozprawy jest opracowanie i wdrożenie mobilnej stacji transformatorowej, która wspiera diagnostykę linii kablowych off-line. Ta innowacyjna jednostka pozwala na efektywne przeprowadzanie pomiarów diagnostycznych bez konieczności wyłączeń zasilania. W pracy szczegółowo opisano konstrukcję i funkcjonalności mobilnej stacji transformatorowej oraz techniki prac pod napięciem, które umożliwiają podłączenie tej stacji do sieci bez wyłączania zasilania. Analiza badań terenowych, przeprowadzonych z wykorzystaniem mobilnej stacji transformatorowej, wykazała ich wysoką efektywność w wykrywaniu wyładowań niezupełnych i innych defektów kabli średniego napięcia. Wyniki badań pozwoliły na dokładną ocenę stanu technicznego badanych kabli oraz zaplanowanie działań naprawczych i prewencyjnych, co przyczyniło się do zwiększenia niezawodności sieci. Podsumowując, praca ta dostarcza cennych informacji na temat diagnostyki wyładowań niezupełnych w kablach średniego napięcia oraz przedstawia nowatorskie rozwiązania techniczne, które znacząco poprawiają zarządzanie sieciami elektroenergetycznymi i minimalizą przerwy w dostawie energii. Wdrożenie mobilnych stacji transformatorowych oraz technik prac pod napięciem jest kluczowym krokiem w kierunku zwiększenia niezawodności i efektywności operacyjnej sieci elektroenergetycznych.

Abstract (EN)

The Ph.D. dissertation titled „Ensuring Continuity of Medium Voltage Network Supply during Failures, Maintenance Works, and Cable Diagnostics” focuses on the development and implementation of modern methods aimed at increasing the reliability of medium voltage power networks. Partial discharges, which are local electric discharges that partially bridge the insulation of cables, pose one of the main threats to their long-term reliability. Early detection and analysis of partial discharges are essential to prevent major failures and reduce network maintenance costs. The dissertation discusses various types of medium voltage cables in detail, including paper-oil insulated and polyethylene insulated cables, along with their characteristic defects. Diagnostic methods, both conventional and unconventional, such as alternating current tests, very low frequency tests, damped alternating current tests, and electromagnetic, electrical, acoustic, and optical detection, are also presented. A central element of the dissertation is the development and application of a mobile transformer station that supports off-line cable diagnostics. This innovative unit allows for effective diagnostic measurements without the need for prolonged power outages. The dissertation provides a detailed description of the design and functionalities of the mobile transformer station and live working techniques, which enable the connection of the station and maintenance, including network modernization, without power interruptions. The analysis of field research results conducted using the mobile transformer station demonstrated their high efficiency in detecting partial discharges and other defects in medium voltage cables. These results allowed for an accurate assessment of the technical condition of the tested cables and the planning of repair actions, which contributed to the increased reliability of the network. In summary, this dissertation provides valuable information on the diagnostics of partial discharges in medium voltage cables and presents innovative technical solutions that can significantly improve the management of power networks and minimize power supply interruptions. The implementation of mobile transformer stations and live working techniques is a crucial step towards increasing the reliability and operational efficiency of power networks.

Keywords PL
niezawodność sieci elektroenergetycznej
wyładowania niezupełne
diagnostyka linii kablowych
zasilanie awaryjne
Keywords EN
power network reliability
partial discharges
cable line diagnostics
emergency power supply
Durak, S. (2024). Zapewnienie ciągłości zasilania sieci średniego napięcia podczas awarii, prac eksploatacyjnych oraz diagnostyki kablowej (, ed.). https://hdl.handle.net/20.500.14629/18682
Loading...
Thumbnail Image
Files
Durak_rozprawa doktorska_2024_...
Request access
Dostęp zamknięty
PDF6.33 MB
License
Closed Access
Closed Access
Accessibility issue?Request a WCAG-compliant file
Publication available in collections
Doctoral Theses
Scientific and Technical Information Centre of Lublin University of Technology
  • ul. Nadbystrzycka 36 C20-618 Lublin
  • Phone Icon+48 81 538 46 86
  • Emailoab@pollub.pl
Repository of Open Collections and Knowledge
About repository
Instructions for depositing
Regulations
Privacy policy
Accessibility statement
DSpace Software
Human Resources Strategy for Researchers (HRS4R) at Lublin University of Technology
Powered by Dspace 10
Copyright Politechnika Lubelska © 2026